Solvent Cleaning

Solvent CleaningTotal Carbon & Total Sulfur ContentThermal PyrolysisKerogen Microscopy & Vitrinite ReflectanceKineticsExtractionProcedure Title: Solvent Cleaning Instrumentation: Soxhlet Extractor apparatusTurnAround Time to sample count1-1001 Week101-2001 Week201-3002 WeeksTheory of Operation:Solvent cleaning is a process of removing the …

Total Organic Carbon

Analysis Title: Total Organic Carbon (TOC)Instrumentation: LECO C230TurnAround Time to sample count1-1001 Week101-2002 Weeks201-3003 WeeksTheory of Operation:• The LECO C230 carbon determinator is a microprocessor-based, software-driven instrument for measurement of carbon content. The LECO C230 …

Total Carbon & Total Sulfur Content

Solvent CleaningTotal Carbon & Total Sulfur ContentThermal PyrolysisKerogen Microscopy & Vitrinite ReflectanceKineticsExtractionAnalysis Title:Total Carbon (TC) & Total sulfur (TS)Instrumentation: LECO SC632 Carbon/Sulfur DeterminatorTurnAround Time to sample count0-1001 Week101-2002 Weeks201-3003 WeeksTheory of Operation: The LECO SC632 …

Thermal Pyrolysis

Solvent CleaningTotal Carbon & Total Sulfur ContentThermal PyrolysisKerogen Microscopy & Vitrinite ReflectanceKineticsExtractionAnalysis Title: Rock-Eval PyrolysisInstrumentation: 2Rock-Eval1Source Rock Analyzer1HawkTurnAround Time to sample count1-1001 Week101-2002 Weeks201-3003 WeeksTheory of Operation:• Pyrolysis is the decomposition of the organic matter …

Extraction

Solvent CleaningTotal Carbon & Total Sulfur ContentThermal PyrolysisKerogen Microscopy & Vitrinite ReflectanceKineticsExtractionProcedure Title: Soxhlet ExtractionInstrumentation: Soxhlet Extractor apparatusTurnAround Time to sample count1-252 Weeks26-503 Weeks51-753 WeeksTheory of Operation:Extraction is a process of dissolving the soluble hydrocarbons …

Kinetics

Solvent CleaningTotal Carbon & Total Sulfur ContentThermal PyrolysisKerogen Microscopy & Vitrinite ReflectanceKineticsExtractionProcedure Title: KINETICSInstrumentation: Rock-Eval 6 (RE-6)Theory of Operation: Kinetics refers to the cracking or breakdown of kerogen molecules by overcoming the barrier of the …

Kerogen Microscopy & Vitrinite Reflectance

Solvent CleaningTotal Carbon & Total Sulfur ContentThermal PyrolysisKerogen Microscopy & Vitrinite ReflectanceKineticsExtractionAnalysis Title: Kerogen Microscopy Analysis Instrumentation:1Safe Air Fume Hood1Centrifuge1Grinding/Polishing Machine1Kerogen Microscopy and Reflected Light Microscopy.TurnAround Time to sample count1-255 Weeks26-506 Weeks51-757 WeeksTheory of Operation:• …

API Gravity

API GravityWhole Oil/Extract Gas ChromatographyMedium Pressure Liquid ChromatographyWhole Oil SARASAT/ARO GCMSIsotope Analysis for LiquidsCompound Specific Isotope Analysis (CSIA)Procedure Title: API Instrumentation: Pycnometer Theory of Operation:• API is a measure of how heavy or light petroleum …

Whole Oil/Extract GC

API GravityWhole Oil/Extract Gas ChromatographyMedium Pressure Liquid ChromatographyWhole Oil SARASAT/ARO GCMSIsotope Analysis for LiquidsCompound Specific Isotope Analysis (CSIA)Procedure Title: Whole Oil/Extract Gas Chromatography (GC)Instrumentation: 1Agilent 6890 N GC System / Agilent 7683 B Series Injector1Hewlett …